Mitsubishi Electronics BNP-C3040D Welder User Manual


 
4. Servo Adjustment
4 - 41
<Outline of system configurations and corresponding parameter settings>
[1] Spindle controls power supply, vertical axis is a 1-axis unit (vertical axis: Z axis)
MDS-C1-V2
X axis, Y axis
MDS-C1-V1
*Z axis
MDS-C1-SP
Spindle
MDS-C1-CV
Power supply
X axis Y axis Z axis (Vertical axis) Spindle
Axis
Parameter
MDS-C1-V2 MDS-C1-V1 MDS-C1-SP
SV048 - - Set by adjustment
SV055 - - Same value as SV048
SV056 - -
Same value as Z axis
rapid traverse time
constant
Spindle parameter
SP033/bitF=1
[2] Spindle controls power supply, vertical axis is a 2-axis unit (vertical axis: Z axis)
MDS-C1-V1
X axis
MDS-C1-V2
Y axis, *Z axis
MDS-C1-SP
Spindle
MDS-C1-CV
Power supply
X axis Y axis Z axis (Vertical axis) Spindle
Axis
Parameter
MDS-C1-V1 MDS-C1-V2 MDS-C1-SP
SV048 -
Same value
as Z axis
Set by adjustment
SV055 -
Same value
as Z axis
Same value as SV048
SV056 -
Same value as Y axis
rapid traverse time
constant
Same value as Z axis
rapid traverse time
constant
Spindle parameter
SP033/bitF=1
NC
NC