Mitsubishi Electronics BNP-C3040D Welder User Manual


 
2. Wiring and Connection
2 - 23
(1) Connection for semi-closed synchronous control (when using MDS-C1-V1 drive unit)
MDS-C1-V1
(Slave axis)
MDS-C1-V1
(Master axis)
Master axis
Slave axis
Detector cable
CNV12
MDS-B-SD
Signal distribution unit
CN2CN2
CN2A
CN2B
CN2
CN3
SH21
SH21
Parameter settings
No. Abbrev. Parameter name Description
Set the detector type. The value determined for each motor type is input to “xx” in the
following table.
Motor end detector type
OSE104/OSE105 OSA104 OSA105
Speed command
synchronous
control
Not compatible
Master axis =11xx
Slave axis =C1xx
Master axis =22xx
Slave axis =C2xx
Current
command
synchronous
control
Not compatible
Master axis =11xx
Slave axis =CCxx
Master axis =22xx
Slave axis =CCxx
SV025 MTYP Motor/detector type
(Note) A system in which two MDS-C1-V1 unit are used is not compatible with incremental system.