2 On the Redundant Configuration page, click Switch Server Role.
The system initiates a failover to the other server.
Discontinue Redundancy on a Polycom CMA 5000 System
Configuration
In some circumstances, you may need to discontinue redundancy. Use this
procedure to do so, but only when the system is in a valid redundant state.
To discontinue a redundant Polycom CMA 5000 system configuration:
1 Log into the CMA 5000 system using the virtual IP address.
2 Failover to the redundant server. See page 437.
3 On the redundant server:
a Go to Admin > Server Settings > Database.
b On the Database page, deselect the Use an external SQL Server
database check box.
c Click Update.
The redundant server restarts.
4 On the primary server:
a Go to Admin > Server Settings > Redundant Configuration.
b On the Redundant Configuration page, click Reset Redundant
Configuration.