Cisco Systems OL-18611-01 Work Light User Manual


 
90-55
Cisco Unified Communications Manager Administration Guide
OL-18611-01
Chapter 90 Gateway Configuration
Port Configuration Settings
Redirecting Number IE
Delivery— Inbound
Check this check box to accept the Redirecting Number IE in the
incoming SETUP message to the Cisco Unified Communications
Manager. (The UUIE part of the SETUP message includes the
Redirecting Number IE.)
Uncheck the check box to exclude the Redirecting Number IE.
You use Redirecting Number IE for voice-messaging integration
only. If your configured voice-messaging system supports
Redirecting Number IE, you should check the check box.
Send Extra Leading Character
in Display IE
Check this check box to include a special leading character byte
(non ASCII, nondisplayable) in the DisplayIE field.
Uncheck this check box to exclude this character byte from the
Display IE field.
This check box only applies to the DMS-100 protocol and the
DMS-250 protocol.
Default leaves this setting disabled (unchecked).
Setup non-ISDN Progress
Indicator IE Enable
Default leaves this setting disabled (unchecked).
Enable this setting only if users are not receiving ringback tones on
outbound calls.
When this setting is enabled, the Cisco Unified Communications
Manager sends Q.931 Setup messages out digital (that is,
non-H.323) gateways with the Progress Indicator field set to
non-ISDN.
This message notifies the destination device that the Cisco Unified
Communications Manager gateway is non-ISDN and that the
destination device should play in-band ringback.
This problem usually associates with Cisco Unified
Communications Managers that connect to PBXs through digital
gateways.
MCDN Channel Number
Extension Bit Set to Zero
To set the channel number extension bit to zero, check the check
box. To set the extension bit to 1, uncheck the check box.
This setting only applies to the DMS-100 protocol
Send Calling Name in Facility
IE
Check the check box to send the calling name in the Facility IE
field. By default, the Cisco Unified Communications Manager
leaves the check box unchecked.
Set this feature for a private network that has a PRI interface that is
enabled for ISDN calling name delivery. When this check box is
checked, the calling party name gets sent in the Facility IE of the
SETUP or FACILITY message, so the name can display on the
called party device.
Set this feature for PRI trunks in a private network only. Do not set
this feature for PRI trunks that are connected to the PSTN.
Note This field applies to the NI2 protocol only.
Table 90-7 Digital Access PRI Port Configuration Settings (continued)
Field Description