Mitsubishi Electronics 60/60S Router User Manual


 
3. Tool Offset (L system)
3.1 Wear Data
I-80
Refer to "3 (II). Tool Offset (M system)" for M system.
3.1.3 Tool Wear and Tool Length Data Setting Mode (incremental/absolute)
There are two types of selection method in the absolute value setting or incremental value setting for the
tool offset data: the mode selection method and the menu selection method.
The required method is selected with the parameter #1136 optype.
A
bsolute
setting
(Old)
Incremental setting
(
New
)
(Example) Incremental/absolute value setting
Setting Display
• Incremental value setting
# (2) ( - 0.1) #2 X-100.100
Absolute value setting
# (2) ( - 100.1) #2 X-100.100
Display
#2 X -100.000
(1) Mode selection method (#1136=0)
(a) Change over to the incremental value setting mode
Set I in # ( ), then press the
INPUT
key.
# ( I) X ( ) Z ( )
[TOOL DATA]
#I:INC. #A:ABS.
"#1: INC." is highlighted, and the mode becomes the
incremental value setting mode.
(b) Change over to the absolute value setting mode
Set A in # ( ), then press the
INPUT
key.
# ( A) X ( ) Z ( )
[TOOL DATA]
#I:INC. #A:ABS.
"#A: ABS." is highlighted, and the mode becomes the
absolute value setting mode.
(Note)
The mode is held even if the screen is changed or the power is turned OFF.