Mitsubishi Electronics 60/60S Router User Manual


 
6. Data In/Out
6.3 PROGRAM ERASE
I-254
(3) To erase all machining programs registered in memory
To erase all of machining programs 1~99999999 registered in memory, perform the following:
# ( ) DATA ( CLR )
ERASE COMPLETE
# ( ) DATA ( )
Press the
INPUT
key.
Set "CLR" in DATA ( ).
# ( )
DATA ( C
L R )
ERASE EXECUTION
# ( ) DATA ( CLR )
PROGRAM ENTRY 0 REMAIN 200
CHARACTER 0 REMAIN 64000
<PROGRAM> <CHR> <ST> <COMMENT>
Check the PROGRAM FILE screen.
1) All machining program erase is
executed and terminated almost in a
moment. The message "ERASE
COMPLETE" is displayed in the
message field and the data setting
area becomes blank.
1) "PROGRAM ENTRY" is set to 0 and
"REMAIN" is set to the maximum number
of programs defined in the specifications.
2) "CHARACTER" is set to 0 and "REMAIN"
is set to the maximum number of stored
characters defined in the specifications.
The number of programs and the number
of characters are as listed below
according to the specifications:
Tape storage
length
Number of
programs
Number of
characters
40m 64 17500
80m 128 32000
160m 200 64000
320m 200 128000
600m 400 236250
1280m 1000 512000
2560m 1000 1024000
5120m 1000 2048000
3) The PROGRAM FILE screen becomes
blank, indicating that no programs are
registered.
1) No value needs to be entered in #
( ).