6. Data In/Out
6.1 DATA INPUT
I-229
6.1.3 Inputting Tool Offset Data
Data which is output by tool offset data output operation can be input.
Data which is created in the same format as output data can be input as tool offset data and workpiece
coordinate offset data.
(Note) Tool offset data input operation cannot be made during automatic operation.
(1) Inputting tool offset data
Set the data type to tool data.
# ( 2
) DATA ( )
# ( 2 ) DATA ( )
1) Paper tape read is initiated. The contents of
input data and message "DATA IN
EXECUTION" are displayed.
2) When all data to the end has been input and
the tape end code % (EOR) is read, data input
ends with message "DATA IN COMPLETE"
displayed.
Press the
INPUT
key.
<INPUT DATA>
G10 L10 P···;
<COMP. DATA>
DATA IN EXECUTION
# ( 2 ) DATA ( )
<INPUT DATA>
%
<COMP. DATA>
DATA IN COMPLETE
# ( ) DATA ( )
(2) When an error occurs during offset tape input:
If an error occurs during offset tape input, the error number and error message will be displayed on the
screen. At this time, input operation stops. (E02, E25, E71, or E86 error)
In this case, data input can resume by repressing the
INPUT
key while the input screen is being
displayed.
The data input can resume, beginning with the block next to the erroneous block, which is not input in
this case.