Mitsubishi Electronics 60/60S Router User Manual


 
2. Monitor
2.5 Resuming the Program
I-66
(3) Type 3 (T command restart) restart search
Press the
INPUT
key.
1) The block containing the T
command executed last will be
searched for.
2) The "RESEARCH EXECUTION"
message appears during the
search and upon its completion
the "RESEARCH COMPLETE"
message is displayed.
3) If each axis is at a (–) position
from the value set in the restart
limit (#2072 rslimt), the error
"E98 CAN'T RESEARCH" will
occur. Manually return the axis
to a position where the error will
not occur, and then search.
Set "3" in TYPE T ( ) in the setting
area.
O ( ) N ( ) - ( )
P ( ) T ( 3 ) M ( )
1) The data set in the setting areas
other than T ( ) and M ( ) will be
ignored.
2) Designate "1" in M ( ) when
using the tape mode.
M: MODE <0> MEMORY <1> TAPE
T: TYPE <0> UNMODLE <1> TYPE 1 <2> TYPE 2
<3>T-TYP
O ( ) N ( ) - ( ) P ( ) T(3) M(0)
M: MODE <0> MEMORY <1> TAPE
T: TYPE <0> UNMODLE <1> TYPE 1 <2> TYPE 2
<3>T-TYP RESEARCH EXECUTION
O ( ) N ( ) - ( ) P ( ) T(3) M(0)
[PROGRAM RESTART] MONITOR 5 .1/ 2
O 1000 N 5 - 0
<SUB> O N -
[RESTART- (G54)] [RESTART-R]
X -130.000 X -150.000
Y -10.000 Y -150.000
Z 0.000 Z 0.000
C 0.000 C 0.000
N51 Y-70.;
N52 X-20.;
M: MODE <0> MEMORY <1> TAPE
T: TYPE <0> UNMODLE <1> TYPE 1 <2> TYPE 2
<3>T-TYP RESEARCH COMPLETE
O ( ) N ( ) - ( ) P ( ) T( ) M( )
(Note) Restart type 3 is valid only with the lathe system.