Mitsubishi Electronics 60/60S Router User Manual


 
2. Monitor
2.1 POSITION
I-23
2.1.1 Total Clear of Screen
If you do not use the unit for extended periods, clear the entire screen to prevent deterioration of the display
unit by the following procedures.
(1) Select 1st menu
POSI
on the MONITOR screen and press the
SHIFT
and
C.B
CAN
keys to clear
total
screen.
(2) If you want to display screen after clearing of total screen, press a function select key such as
MONI-
TOR
to
display the screen you desire.
2.1.2 Position Display Counter Zero and Origin Zero
Counter Zero
The POSITION display only is set to zero and the absolute value data remains unchanged.
Origin Zero
This sets both POSITION display and absolute value data to zero.
It is equivalent to G92 X0 Y0 Z0 ;.
(Note1) Origin zero is valid only when #1123 origin is set to 0.
(Note2) Counter zero and origin zero are disabled in the current value B.
In the following operations, the
INPUT
key has
the counter zero function and the
C.B
CAN
key
has the origin zero (set zero) function.
Press the address key
X
.
1) The address indication corresponding
to the key is highlighted.
Press the
INPUT
key (counter zero)
or
C.B
CAN
key (origin zero).
1) The axis position data is set to zero and
the next axis name is highlighted.
2) By repeatedly pressing the
INPUT
key or
C.B
CAN
key, the position data of other axes
can be cleared to zero.
3) Upon completion of zero clear of final
axis, the display is no longer reversed.
4) If you press an axis address key
midway, the address of specified axis is
highlighted.
5) When you press a key other than axis
address key, the display is no longer
reversed.
X -12345.678
Y 1.234
Z 12.345
C 123.456
X -12345.678
Y 1.234
Z 12.345
C 123.456
X 0.000
Y 1.234
Z 12.345
C 123.456
X 0.000
Y 0.000
Z 12.345
C 123.456