Mitsubishi Electronics 60/60S Router User Manual


 
7. Diagnosis
7.9 Auxiliary Axis Parameter
I
-301
(b) Writing auxiliary axis parameters to MR-J2-CT
After backing up the auxiliary axis parameters in the SRAM, turn the NC and MR-J2-CT power OFF,
and replace the MR-J2-CT amplifier.
The replacement amplifier must be initialized beforehand.
After replacing the MR-J2-CT amplifier, turn the NC and MR-J2-CT power. Then, write in the auxiliary
axis parameter data and restore the absolute position.
The data in the CNC SRAM is written to the new amplifier.
The following describes the procedure for writing the auxiliary axis parameters to MR-J2-CT.
[BACKUP] ALARM/DIAGN 9. 11/11
AUX-PARA
#1 MR-J2-CT-> SRAM
#2 SRAM -> MR-J2-CT
ABS POS.
#3 ABS POS RESTORE
#(2) (1) (Y) WRITE COMPLETE
AUX-PRM AUX-MON MENU
Input "(2) (a)" from the BACKUP screen. (a: axis No. (1 to 4))
After inputting, the message "CONTINUE Y/N" will appear for confirmation of the data backup. The
auxiliary axis parameters are written to MR-J2-CT only if "(Y)" is input.
The message "AUX. WRITTING EXEC." will appear when the writing operation is carried out.
The message "WRITE COPLETE" will appear when the writing operation is finished.
If MR-J2-CT is not connected, the message "E01 SETTING ERROR" will occur, and the data will not
be written.
Auto-tuning parameters are written as shown below, using the auto-tuning selection (parameter #7
ATU) of the SRAM data and the MR-J2-CT side.
#7 ATU in SRAM #7 ATU set in MR-J2-CT
Auto-tuning
parameter written
Auto-tuned (0 or 1) Auto-tuned (0 or 1) Not written
Not auto-tuned (2) Auto-tuned (0 or 1)
Written
(Note 1)
Auto-tuned (0 or 1) Not auto-tuned (2)
Written
(Note 1)
Not auto-tuned (2) Not auto-tuned (2)
Written
(Note 1)
(Note 1)
Which parameters can be input depends on the setting of “#7 ATU” parameter.
(Refer to "6.2.7 Outputting Auxiliary Axis Parameter Data" for details on auto-tuning target
parameters.)
(Note 2)
The NC does not hold the MR-J2-CT parameters.
The parameters are held on the MR-J2-CT side.
When the MR-J2-CT unit is replaced, the parameters must be set again in the new unit.