Mitsubishi Electronics 60/60S Router User Manual


 
4. Operation Mode
4.1 Mode Selection Switch
II-7
4. Operation Mode
(Note ) Do not execute the tap retract simultaneously with the operation in the manual (JOG feed, rapid
traverse feed, reference position return, incremental and handle) mode or in the automatic (memory,
tape and MDI) mode.
The simultaneous operation causes the all axes interlock.
4.1 Mode Selection Switch
The MODE SELECT switch is used to determine the controller operation mode.
Jog feed mode:
Select the mode to move the controlled axis
consecutively at manual feedrate.
Rapid traverse feed mode:
Select the mode to move the controlled axis
consecutively at rapid traverse feedrate.
Return to reference position mode:
Select the mode to position the controlled axis
at the machine reference position manually.
Incremental mode:
Select the mode to move the controlled axis at a
given distance.
MODE SELECT MEMORY
RAPID
TRAVERSE
JOG
REFERENCE
POINT
RETURN
MDI
TAPE
HANDLE
INCRE-
MENTAL
Handle feed mode:
Select the mode to move the controlled axis by using the manual handle.
Memory Mode:
Select the mode for memory operation.
Tape mode:
Select the mode for tape operation.
MDI mode:
Select the mode for MDI operation.
(Note 1) See 1.4 for the running state when a change is made to another mode during automatic
operation.
4.2 Jog Feed Mode
The jog feed mode enables the machine to be moved consecutively at the feedrate set by using the
MANUAL FEED RATE switch manually. The jog feed mode is started by using the FEED AXIS SELECT
switch.
See Section 5 for the MANUAL FEED RATE switch.
Operation procedure
Using the MODE SELECT switch, select the jog mode.
Using the MANUAL FEED RATE switch, set the feedrate.
The feedrate unit is the travel distance (mm) per minute.
To move the controlled axis, turn on the FEED AXIS SELECT switch. The
controlled axis is moved while the switch is turned on.
When the switch is turned off, the controlled axis stops with deceleration.
(Note 1) When the MANUAL OVERRIDE switch on the operation panel is turned ON, the override value set
by using the FEED RATE OVERRIDE switch takes precedence over the feedrate set by using the
MANUAL FEED RATE switch.