Mitsubishi Electronics 60/60S Router User Manual


 
6. Operation Panel Switch Functions
6.14 Handle Interruption
II-23
6.14.4 Axis Movement Speed Resulting from Interruption
(1) The movement speed of the axis for which handle interruption is executed, may exceed the rapid
traverse feed rate during rapid traverse feed command (G00) processing in automatic start. To prevent
this, clamp the axis. (The movement speed equals Automatic-start movement speed + Speed resulting
from manual handle interruption.)
(2) The movement speed of the axis for which handle interruption is executed, may exceed the cutting feed
speed during cutting feed command (G01, G02, G03) processing in automatic start. To prevent this,
clamp the axis. (The movement speed equals Automatic start movement speed + Speed resulting from
manual handle interruption.)
(3) If, during automatic start, manual handle interruption is executed, in the same direction, for the axis that
is moving at an external decelerating speed, the axis movement speed may exceed the external
decelerating speed. To prevent this, clamp the axis. (The movement speed equals Automatic start
movement speed + Speed resulting from manual handle interruption.)
(4) If an attempt is made to execute interruption at a speed exceeding the clamp speed, the reading on the
handle scale does not match the distance of interruption.
(5) The handle scale factor depends on the selected input of the manual handle/step scale factor.