Mitsubishi Electronics 60/60S Router User Manual


 
2. Monitor
2.3 COMMAND
I-47
2.3.3 Total Integrating Time Display
By switching the screen from the execution program's monitor screen by using the
NEXT
PAGE
key, the TIME
screen is displayed.
POSI COORDI COMMAND SEARCH MENU
[TIME] MONITOR 3.3/3
O12345678 N12345-12
<SUB> O 1000 N 200-30
# 1 DATE 99/12/14
2 TIME 13:27:59
3 POWER 9999:59:59
4 AUTO OP 0: 0: 0
5 AUTO STL 0: 0: 0
6 EXT TIME1 0: 0: 0
7 EXT TIME2 0: 0: 0
#( ) DATA( ) ( ) ( )
Display item Explanation
O12345678 N1234-12 The currently executing program number, sequence number, and
block number are displayed.
<SUB> O1000 N200-30 When a subprogram is being executed, the program number,
sequence number, and block number of the subprogram are
displayed.
#1 DATE 99/12/14
2 TIME 13:27:59
3 POWER ON 9999:59:59
4 AUTO OP 0: 0: 0
5 AUTO STL 0: 0: 0
6 EXT TIME 1 0: 0: 0
7 EXT TIME 2 0: 0: 0
The date and time are set and displayed. year/month/day
hour : min : sec
The total integrating time in each operation state is displayed.
(1) TIME setting
Set the number, hour, minute, and second corresponding to the TIME to be set.
Set 3 in # ( ).
Set 0 in DATA ( ) ( ) ( )
Press the
INPUT
key.
#3 POWER ON 0: 0: 0
POSI COORDI COMMAND SEARCH MENU
# (3) DATA ( 0 ) ( 0 ) ( 0 )
DATE : Set date (set "YEAR" in last 2 digits of Gregorian calendar)
TIME : Set time in 24-hour mode.
POWER ON : Total integrating time of the time from control unit power ON to OFF.
AUTO OP : Total integrating time of the work time from AUTO STL button pressing in the memory
(tape) mode to M02/M30 or reset button pressing.
AUTO STL : Total integrating time during automatic starting from AUTO STL button pressing in the
memory (tape) mode or MDI to feed hold stop, block stop, or reset button pressing.
EXT TIME 1 : Dependent on PLC sequence.
EXT TIME 2 : Dependent on PLC sequence.
(Note) Integration time (#3 POWER ON to #7 EXT TIME 2): When display reaches the maximum
value (9999:59:59), integration is stopped and the maximum value remains displayed.