Mitsubishi Electronics 60/60S Router User Manual


 
6. Data In/Out
6.2 DATA OUTPUT
I-241
6.2.2 Outputting Tool Offset Data
Tool offset data and workpiece coordinate offset data which is set and displayed on the screen can be
output. The output operation can be made also during automatic operation.
The output tape length varies with the tool offset type, the number of sets, and the offset data numeric. For
the 40-set specification, this length is 3 to 4m for type I and 12 to 16m for type II.
(1) Tool offset data is output as follows:
Set the data type to tool data.
# ( 2
) DATA ( )
# ( 2 ) DATA ( )
<OUTPUT DATA>
G10 L10 P···;
DATA OUT EXECUTION
# ( 2 ) DATA ( )
1) Output to paper tape is started. The contents
of output data and message "DATA OUT
EXECUTION" are displayed.
2) After the tape end code % (EOR) is output,
data output ends with message "DATA OUT
COMPLETE" displayed.
Press the
INPUT
key.
<OUTPUT DATA>
%
DATA OUT COMPLETE
# ( ) DATA ( )
(2) Output tape format
Feed
Data area Feed Feed Feed
E E E E
O O G10L10P· · · O O
R B B R
The data area format is the same as tool offset input (G10) and work offset input (G10) by the program.
The data is output in the order of the tool offset and workpiece coordinate offset data.
(Note) For the multiple system, data will be output following the parameters below.
#1286 ext22/bit1 0: The data for each system will be output.
1: The data for the system selected with the system selection switch will
be output.
#1051 MemTol 0: The output will follow ext22 bit1.
1: The common tool offset data specifications will be used between the
systems, so the same output as the single system will be used.