Mitsubishi Electronics 60/60S Router User Manual


 
3. Tool Offset (L system)
3.1 Wear Data
I
-81
Refer to "3 (II). Tool Offset (M system)" for M system.
(2) Menu selection method (#1136=1)
(a) Change over to the incremental value setting mode
Set value in #( ), X( ) or Z( ), then press
the + INPUT key.
[TOOL TIP OFFSET] TOOL 2.1/4
#I : INC. #A : ABS.
#1 X 0.000 Z 0.000
2 X 0.000 Z 0.000
3 X 0.000 Z 19.700
: : :
: : :
T M
# ( 4 ) X ( )
Z ( )
[POSITION] X 123.456
Z 345.678
+INPUT =INPUT RETURN
(b) Change over to the absolute value setting mode
Set value in #( ), X( ) or Z( ), then press
the = INPUT key.
[TOOL TIP OFFSET] TOOL 2.1/4
#I : INC. #A : ABS.
#1 X 0.000 Z 0.000
2 X 0.000 Z 0.000
3 X 0.000 Z 19.700
: : :
: : :
T M
# ( 4 ) X ( )
Z ( )
[POSITION] X 123.456
Z 345.678
+INPUT =INPUT RETURN
* When the cursor is moved to X( ) or Z( ) then the data key is pressed, =INPUT,+INPUT menu will
appear automatically.
(c) Supplement
• If INPUT key is pressed while = INPUT, + INPUT are displayed, the offset data can be set for mode
selection method.
• = INPUT, + INPUT are displayed until BACK menu key is pressed or other screens are selected.
The screen selection menu is displayed when TOOL OFFSET screen is selected again after other
screens are selected once.
“ Mark of the screen selection menu indicates that the operation menu exist on the screen being
displayed.
• The operation menu is invalid during the tool measurement with manual tool length measurement
function. The operation menu during the tool measurement operates as follows.
1) When the screen select menu is displayed
+ INPUT, = INPUT don’t appear during the tool measurement. If = INPUT, + INPUT with “
“ mark
are pressed during the tool measurement, ERROR (E74) will occur.
2) When the operation menu is displayed
If = INPUT, + INPUT are pressed during the tool measurement, ERROR (E74) will occur.
• = INPUT, + INPUT are invalid during the manual numerical command mode.
If = INPUT, + INPUT are pressed during the manual numerical command mode, ERROR (E74) will
occur. If the screen selection menu displayed with “
“ mark is pressed during the manual numerical
command mode, ERROR (E74) will occur.
• When the offset memory No. not displayed on the screen is set in setting area # ( ), the screen
corresponding to the offset memory No. set in will appear by pressing = INPUT,+ INPUT key of one
time. The offset data will be set by pressing = INPUT, + INPUT key again.
• When the tool nose point data is set on the NOSE-R screen, the absolute setting is selected whichever
of = INPUT and + INPUT key is pressed.