5. Stored Stroke Limit
5.1 Stored stroke limit I
III-30
5.1 Stored stroke limit I
This is a stroke limit function used by the machine maker. The boundary is set with the parameters (axis
specification parameters "#2013 OT–" and "#2014 OT+"). The outside of the set boundary is the prohibited
range.
When used with the stored stroke limit II function, the narrow range designated by the two types becomes the
movement valid range.
Basic machine coordinate system
Point 1
Prohibited range
Machine movement valid range
– setting value
Prohibited range
Point 2
+ setting
value
The following values are set
with the coordinate values in
the basic machine coordinate
system.
Point 1: #2014 OT+
Point 2: #2013 OT–