Mitsubishi Electronics 60/60S Router User Manual


 
6. Data In/Out
6.5 PROGRAM FILE
I-264
(Note 1) If a large number of short programs are registered or edit operation is performed frequently, the
memory use efficiency lowers because of the memory configuration and (CHARACTER +
REMAIN) becomes less than the maximum number of available characters that are stored. If the
difference between them is extremely large, the condense function can be used to improve the
memory use efficiency.
(Note 2) If preparing comment, space (
SP
) can be written in it. But, the space is ignored after
registration
for efficient use of memory.
(Note 3) When using the 2-part system, the system name of the currently selected system is displayed as
$1 (system 1) and $2 (system 2). This is not displayed when using a 1-part system. (Only L
system)
(Note 4) Whether to show or hide name of the selected system can be switched with the parameters. The
list of machining program numbers can also be switched with the parameters.
#1050
MemPrg
#1285
ext21/bit0
#1286
ext22/bit0
System name display Program number list display
0, 2, 4, 6 -
-
The name of the selected
system is not displayed.
The numbers of the machining
programs registered in the
memory common for the
systems are listed.
1, 3, 5, 7 OFF -
-
OFF
The name of the selected
system is displayed.
The numbers of the machining
programs registered in the
memory for the selected system
are listed.
ON
ON
The name of the selected
system is not displayed.
The numbers of the machining
programs registered in the
memory for all systems are
listed.