Mitsubishi Electronics 60/60S Router User Manual


 
Appendix 4. Registering/Editing the Fixed Cycle Program
4.6 Standard Fixed Cycle Subprogram (For M system)
IV-15
4.6 Standard Fixed Cycle Subprogram (For M system)
G81 (O810) Drill, spot drill
Fixed cycle block 1 movement command
Check for fixed cycle invalidity.
Inhibit single block stop.
Return.
G82 (O820) Drill, counter boring
Fixed cycle block 1 movement command
Check for fixed cycle invalidity.
Inhibit single block stop.
Dwell.
Return.
G83 (O830) Deep hole drill cycle
Fixed cycle block 1 movement command
Check for fixed cycle invalidity.
Define the cutting amount.
Initialize the return amount (total cutting amount).
Inhibit single block stop.
Define the return amount of the next block.
Calculate the feed amount.
Feed.
Does the total cutting amount (return amount)
exceed the cut amount?
Cutting feed
G. 1 ;
1F [#30] GOTO1 ;
Z#2 G#6 H#7 ;
#2 = ##5
#3003 = #8 OR 1 ;
G1 Z#3 ;
#3003 = #8 ;
G0 Z #3 #2 ;
N1 M99%
G. 1 ;
1F [#30] GOTO1 ;
Z#2 G#6 H#7 ;
#2 = ##5
#3003 = #8 OR 1 ;
G1 Z#3 ;
G4 P#4 ;
#3003 = #8 ;
G0 Z #3 #2 ;
N1 M99%
G. 1 ;
1F [#30] GOTO2 ;
#29 = #11
#28 = 0
Z#2 G#6 H#7 ;
#2 = ##5
#3003 = #8 OR 1 ;
DO 1 ;
#28 = #28 #11
#26 = #28 #29
Z#26 ;
IF [ABS [#28] GE [ABS [#3] ] ] GOTO 1 ;
G1 Z#29 ;