Mitsubishi Electronics 60/60S Router User Manual


 
5. Program
5.2 Menu Function
I-176
(3) MDI data setting
(1)
Enter MDI data by pressing the
data keys in sequence according
to the machining program listing.
N1 G28 X0 Y0 Z0 ;
N2 G92 X0 Y0 Z0 ;
N3 G00 X-100. Y-100. ;
N4 G01 X-300. F2000;
N5 Y-300. ;
N6 X-100. ;
N7 Y-100. ;
N8 M02 ;
N1G28X0Y0Z0;N2G92X0Y0Z0;N3G00X-100.Y-
100.;N4G01X-300.F2000;N5Y-300.;N6X-100
.;N7Y-100.;N8M02;
EDITING
1) The data is written into the MDI memory
area.
2) It is displayed on every line per block.
3) The message "MDI SETTING COMPLET"
is displayed and MDI operation is enabled.
The running start position is the starting
block of data. The cursor is displayed in the
starting block.
(2)
Press the
INPUT
key.
N1 G28 X0 Y0 Z0 ;
N2 G92 X0 Y0 Z0 ;
N3 G00 X-100.Y-100.;
N4 G01 X-300.F2000 ;
N5 Y-300.;
N6 X-100.;
N7 Y-100.;
N8 M02 ;
%
MDI SETTING COMPLET
CAUTION
Because of key chattering, etc., during editing, "NO NOS. FOLLOWING G" commands become a
"G00" operation during running.
(Note 1) If the
INPUT
key is not pressed, data is simply displayed on the screen and is not actually
stored in
memory. Be sure to press the
INPUT
key.
(Note 2) See 5.3 for details of key operation to set MDI data.
(Note 3) Check the "MDI SETTING COMPLET" message before starting MDI operation. If the "EDITING"
or "MDI NO SETTING" message is displayed, MDI operation cannot be started.
If the
INPUT
key is
pressed at the time, the "MDI SETTING COMPLET" message is displayed.
(Note 4) If the system is changed while correcting the MDI data, the corrections will be canceled.