Mitsubishi Electronics 60/60S Router User Manual


 
8. High-speed Program Server
8.2 Host (Compatible with M60 Series)
I-324
8.2.2 Downloading (IC to host)
No. < NAME > < BYTE > < DATE > <TIME>
1 12345678.PRG 12345678 1999 /04/29
2 1000.prg 123 /05/03 09:32
3 Test.prg 123 /05/04 09:32
A
n example of registering the machining program
file "Test.prg (file No. 3)" saved in the host
computer as "2000.prg" in the IC card is
explained in this section.
COPY HOSTSET HOST
#(2) ( )
( )
(1) Input "2" in the setting area # ( ), and press
the cursor key
.
COPY HOSTSET HOST
#(2) ( )
( )
(2) Input the file No. of file name to be uploaded
from the file list in the setting area ( ), and
press the cursor key
.
* Up to 12 uppercase alphabetic characters
can be designated as the file name.
* The values 1 to 10 are used only to
designate the "file No.".
COPY HOSTSET HOST
#(2) ( )
( )
(3) Input the program No. to enter into the IC as
a number in the following setting area. Up to
eight digits can be designated for the
program No.
(4) Press the
INPUT
key.
The message "
DATA IN EXECUTION
" will
appear. When the transmission is completed,
the message "
DATA IN COMPLETE
" will
appear, and the setting area will be cleared.
HOST IC CARD MENU
DIR. ( )
DATA IN EXECUTION
(Note 1) The machining program being input from the host computer cannot be automatically run. (The
host computer machining program cannot be searched.)
(Note 2) The input cannot be canceled.
(Note 3) Operations on the screen cannot be carried out during the input.