Mitsubishi Electronics 60/60S Router User Manual


 
4. Absolute Position Detection System
4.3 Starting up Absolute Position Detection System
III-18
(3) Zero-point initialization
The jog or handle is used with the "ABS. POSITION SET" screen to perform zero-point initialization. The
progress of the initialization operation is displayed in the STATE field of the same screen.
The operation procedure will differ
depending on the zero point
initialization method. Each procedure is
explained below.
(a) Machine end stopper method
(#2049 type: 1)
The machine end stopper method
includes two initialization modes:
manual and automatic.
(i) Manual initialization
With this method, the axis is
pressed against the machine end
stopper using handle or JOG.
Before performing zero-point
initialization, specify the following
parameter (for details, see Alarm/
Parameter Manual):
ABS-SRV ADJUST HISTORY CMPOSIT MENU
[ABS. POSITION SET] ALARM/DIAGN 5.2/2
<X> <Y> <Z> <C>
TYPE NO-STOPPER STOPPER NO-STOPPER STOPPER
STATE NG NG NG NG
TO END -12345.678 0.000 1.234 0.000
MACHINE -12345.678 NOT PASS 0.000 NOT PASS
#
0 INIT SET 0 1 1 1
1 ORIGIN 0 0 1 0
2 ZERO -12345.678 0.000 1.234 0.000
#( ) ( ) ( ) ( ) ( )
#2054 clpush (Current limit)