3. Tool Offset (M system)
3.3 Tool Life
I-129
Refer to "3 (I). Tool Offset (L system)" for L system.
3.3.3 TOOL LIFE Data Display and Setting (TOOL LIFE Data Screen Page 2)
(1) Data display
When the menu key
NEXT
PAGE
is pressed on the HEAD, NEXT, GROUP list screen (previously
described),
the TOOL LIFE screen is displayed.
The data in the group previously set is displayed. If no data is set, the screen is displayed with blank in
the data area.
Press the
INPUT
key.
Set G123 in # ( ).
[TOOL LIFE] TOOL 4.2/2
GROUP 123
# TOOL NO. ST FROM L-CMP R-CMP AUX LIFE USED
1 12345678 4 220 -345.678 100.000 12345 1234 234(min)
2 1234567 3 120 112.340 30.000 11111 123 45(min)
3 123456 2 111 122.220 20.000 44444 100 50(set)
4 12345 1 002 11.234 100.123 100 50 15(cyc)
5
6
7
8
9
10
# ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( )
OFFSET REGIST LIFE MENU
Set necessary data of TOOL NO. to
USED in the corresponding
parenthesis pairs in the ascending
order of the (#) numbers, then press
the
INPUT
key.
Set G in # ( ), then press
the
INPUT
key.
(2) Data registration
Select TOOL LIFE data screen for the group in which data is to be registered.
OFFSET REGIST LIFE MENU
[TOOL LIFE] TOOL 4.2/2
GROUP 123
# TOOL NO. ST FROM L-CMP R-CMP AUX LIFE USED
1 12345678 4 220 -345.678 100.000 12345 1234 234(min)
2 1234567 3 120 112.340 30.000 11111 123 45(min)
3 123456 2 111 122.220 20.000 44444 100 50(set)
4 12345 1 002 11.234 100.123 100 50 15(cyc)
5
6
7
8
9
10
# ( 5) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( )
The data is registered, and a setting
number incremented by one is set in #().
(Note 1) If TOOL NO. and ST (status) are not set, setup data becomes invalid.
(Note 2) A single tool cannot be registered in more than one group.
The tool data registered in group 123 is
displayed in the registration order. If the data
exceeds one screen, the remaining data can
be seen by using the