Cisco Systems 4.1 Dust Collector User Manual


 
A-76
User Guide for Resource Manager Essentials 4.1
OL-11714-01
Appendix A RME Troubleshooting Tips and FAQs
Software Management
SWIM1041 This device upgrade
requires opening an
SSH/Telnet connection to
the device.
Enable password is not
configured correctly in
Device and Credential
Repository.
Make sure that the appropriate SSH/Telnet
passwords are configured correctly in Device
and Credential Repository.
SWIM1042 The amount of Bootflash
on the device may not be
enough to run the selected
image.
The amount of Bootflash on
the device may not be enough
to run the selected image.
Specify the Bootflash size for the image by
editing the attributes of the image stored in
the software repository, increase the
Bootflash size for the device, or select a
different image for upgrading.
SWIM1043 Runtime error while
performing Bootloader
image verification.
Selected image version may
not be in the standard version
format.
Retry the job. If the problem persists, send the
debug logs to Cisco Technical Assistance
Center (TAC).
The debug logs are available at this location:
On Windows:
NMSROOT\log\swim_debug.log
On Solaris:
/var/adm/CSCOpx/log/swim_debug.log
SWIM1044 Bootflash partition will be
erased before copying new
image.
Selected Bootloader image
does not fit in available space
on Bootflash.
Select a different Bootloader image if
available.
SWIM1046 Selected software does not
fit in selected Flash
partition.
Selected software image does
not fit in the available space
on Bootflash.
Select a different Flash partition for
upgrading.
SWIM1047 Minimum software version
required for MICA image
upgrade is not known.
None. Select the image in the software repository
and update the minimum system software
version using View/Edit Image Attributes
option.
SWIM1048 The system software that is
active on the device,
cannot run the selected
image.
The system software that is
active on the device, is not
compatible with the selected
image.
Select a different image that can be upgraded
with the current system software or upgrade
the system software to Software Version.
SWIM1049 The selected image
requires Flash to be erased
during image upgrade.
None. Check whether you have performed the
necessary backup.
SWIM1050 Read-Write SNMP
community string is not in
the Device and Credential
Repository.
The Read-Write SNMP
community string is not
available in the Device and
Credential Repository.
Add Read-Write community string for the
device in the credentials repository.
Message-ID Error Message Probable Cause Possible Action