Appendix A RME Troubleshooting Tips and FAQs
cwcli export
cwcli export
This section provides the FAQs for the cwcli export tool:
Q.What does cwcli export do?
Q.What is ComputerSystemPackage Class?
Q.Where does cwcli export collect the configuration information from?
Q.Is the containment hierarchy in inventory schema exactly the same as that in CIM?
Q.What is an XSD file?
Q.What is the AdditionalInformation tag in the inventory schema used for?
Q.How do I know what fields come under AdditionalInformation?
Q.Where can I find information specific to a particular node which I can see in detailed device
information but not in cwcli export.?
Q.How can I make use of the servlet interface?
Q.How can I get data for some particular entity from devices which are managed by different RME
servers?
Q.While using the -m option, can I use more than one E-mail id?
Q.Where can I get the descriptions of each node in the schema?
Q.Why am I getting parse error when trying to parse some of the output files?
Q.
What does cwcli export do?
A.
cwcli export is a command line tool that also provides servlet access to export inventory,
configuration and change audit data. You can use this tool to export inventory, configuration archive,
and change audit data for devices in Resource Manager Essentials (RME), in the XML format.
CCLI0011 The specified version of
the configuration does
not exist.
You have entered an invalid
version of the configuration.
Use the listversions command to see the
available versions and enter an existing
version
CCLI0012 No baseline templates
exist for this device.
None. Use the listversions command to see the
available baseline templates.
CCLI0013 Data file does not contain
any device.
None Add the devices in the data file and try again
CCLI0014 The job could not be
created because of the
errors reported.
This problem occured because of
any of the following:
You have entered invalid
arguments.
The data file is missing some
parameters.
Do either of the following, depending on
what caused the problem:
Verify whether you have entered valid
arguments.
Update the data file if there are missing
parameters.
CCLI0015 You should not use the -f
option with more than
one device.
Multiple devices are specified for
the command to be executed
along with -f option
Use the -input option to specify the file for
every device
Message-ID Error Message Probable Cause Possible Action